Chapter two – installation – HP Integrity NonStop H-Series User Manual
Page 18

Chapter Two – Installation
Tandem 5142-xSE Rackmount Tape Subsystems User Guide
8
2.5
Setting the Subsystem SCSI ID:
The 5142-xSE is a SCSI device. Each device connects to your system through the SCSI bus and MUST
have a unique SCSI ID in order for your computer to recognize it. There are not any requirements about
the order or position of the SCSI IDs; the only requirement is that no duplicate IDs exist. Devices on the
SCSI bus malfunction if two or more devices have identical SCSI IDs. The subsystem SCSI ID must be 5
for connection to the Multifunction Controller (MFC). For 3214 tape controller connection, valid IDs
are 4 and 5.
2.5.1
Hold in the mode switch while powering on the computer. The following displays appear and
cycle at a two second interval.
Mode
Switch
*Set-Up*
Release
Button
to Start
Enter
Set-Up 1
PRESS to
Select
Enter
Set-Up 2
PRESS to
Select
Enter
Set-Up 3
PRESS to
Select
Exit
Set-Up
PRESS to
Select
Figure 3
Setup menus
2.5.2
Push the mode switch when Setup 1 displays. The following screens appear and cycle at a two
second interval.
Enter
Set-Up 1
PRESS to
Select
Tape ID:
[00]
*NOT sel
ectable*
Rwr% 0.5
Ecc: 0.5
PRESS to
alter
Exit
Set-up 1
PRESS to
Select
SCSI ID:
[00]
PRESS to
Alter
Density:
[FF]
*NOT sel
ectable*
Tape
Term:On
*NOT sel
ectable*
Figure 4
Setup 1 configuration menu