Powering on and off – HP Cisco MDS 9124e Fabric Switch for BladeSystem c-Class User Manual
Page 32

Managing the Switch
32
7.
Create an admin password when prompted by the switch.
8.
Continue with the setup configuration and enter the appropriate information that matches the
Cisco MDS 9124e Switch that you removed.
9.
Install the same Cisco MDS SAN-OS release as was installed on the Cisco MDS 9124e Switch
that was removed. Refer to
and the
10.
I
f Cisco MDS SAN-OS licenses were installed on the Cisco MDS 9124e Switch that was
removed, install the appropriate licenses on the replacement switch.
11.
If you want all ports to be shut when restoring the switch configuration, edit the last backed up
switch configuration file and change all the interface ports to shutdown. For example:
switch# interface bay1
switch# port-license acquire
switch# no shutdown <- change to shutdown
12.
Save the switch configuration file after making your edits.
13.
Restore the switch configuration from the remote server.
14.
Verify that all ports acquire a license, using the following command:
switch# show port-license
15.
I
f all ports have not been acquired, acquire them. Refer to the
and
for
instructions.
16.
Reset the SNMP admin password to enable Device Manager and Fabric Manager SNMP login.
and the
for instructions. The following example shows the CLI
commands:
switch# config t
switch(config)# snmp-server user admin auth md5 new password
switch(config)# do copy running-config startup-config
17.
Connect all external fibre channel cables in the same port location as before. All interfaces
should remain in the shutdown state until you re-enable them on the switch using the no
shutdown
command.
18.
Verify that the switch successfully joins the fabric.
Powering on and off
Cisco MDS 9124e Switch power is provided by the enclosure. The switch will run the Power-On Self
test (POST), a series of diagnostic tests run by a switch after it is powered on, by default each time
power to the enclosure is turned on. The POST process can last as long as three minutes.
To remove power from the switch, remove it from the enclosure interconnect bay.
NOTE:
Each time the Cisco MDS 9124e Switch is powered on, its settings are restored to the
startup configuration.
- Cisco MDS 9020 Fabric Switch SN6000C Fibre Channel Switch Cisco MDS 9120 Fabric Switch Cisco MDS 9216 Fabric Switch Cisco MDS 9140 Fabric Switch Cisco MDS 9500 Director Switch Cisco MDS 8Gb Fabric Switch for HP BladeSystem c-Class SN8000C Director Switch Cisco MDS 9216i Fabric Switch StoreFabric SN8500C Director Switch Cisco MDS 9134 Fabric Switch C-series Switch Expansion Upgrades Cisco MDS 9222i Multiservice Modular Fabric Switch Cisco MDS 9124 Fabric Switch Cisco Nexus 5000 Converged Network Switches Cisco MDS 9216A Fabric Switch