beautypg.com

Update the system coldload and shutdown procedures, Install the autosync ems templates, Install the nonstop autosync ems templates – HP NonStop G-Series User Manual

Page 34: Privileged asysync/asysyncp

background image

Installation

HP AutoSYNC User’s Guide522580-015

2-8

Update the System Coldload and Shutdown

Procedures

If system security is set such that the Authorizer cannot log down to another user ID,
the following options are available:

1. Configure all scheduled synchronizations with the same user id as the AutoSYNC

Authorizer. All other users must request one-time synchronizations.

2. Configure multiple AutoSYNC environments, each with its own MAPDB and

monitor process. Configure each environment to have a different Authorizer, either
by starting the monitor process with a different user ID or by using the
AUTHORIZE command. Then, each user can use the AutoSYNC environment
which corresponds to that user ID.

3. Enable AutoSYNC to operate in a privileged mode. This is the simplest method,

but requires a privileged ASYSYNCP object file. To use this method, follow the
instructions described below in

Privileged ASYSYNC/ASYSYNCP

.

Privileged ASYSYNC/ASYSYNCP

Two circumstances may require the use of a privileged ASYSYNC or ASYSYNCP
process:

If, on the local system, the AutoSYNC Authorizer does not have the privileges to
perform a log down to another user ID, one of the options is to license the local
ASYSYNCP process. See

Bypassing Disabled Log Down

on page 4-7 for details.

For the synchronization of file sets that contain object files with license or progid
attributes, ASYSYNC (or ASYSYNCP if synchronizing over TCP/IP) on the remote
system must operate under a local user ID. A local user ID is required to perform
both scheduled and one-time synchronizations. See

Preserving Security Attributes

on Remote Destinations

on page 3-17 for details.

Update the System Coldload and Shutdown Procedures

The monitor process is started after TMF has been started and before any file
synchronization is attempted. It is advisable to incorporate the restart of the monitor
process with the other operational steps that normally follow a system cold load. The
monitor is started by the

START MONITOR

command. The user ID that starts the

monitor process must have read access to the SysDB and MapDB tables. The user ID
that starts the monitor process may also be the AutoSYNC authorizer; consult

The

AutoSYNC Authorizer

on page 4-1. If the syncusers were suspended prior to shutting

down AutoSYNC, as recommended below in

Shutting Down AutoSYNC

, you will need

to add a step to activate the syncusers using the

ACTIVATE SYNCUSER

command.

Update the shutdown procedures to include the shut down steps described below in

Shutting Down AutoSYNC

.

Install the AutoSYNC EMS templates

The AutoSYNC EMS templates are in the file ZASYTMPL. Please refer to the HP EMS
template installation instructions to perform this step.

This manual is related to the following products: