Page 5-16

Field

Description

Startup Event

Configurable field; determines when the alarm is to be
triggered.

rising — alarm is triggered when the event rate

rises above the threshold.

falling — alarm is triggered when the event rate

falls below the threshold.

rising and falling — alarm is triggered when the

event rate rises above or falls below the thresh-
old.

Threshold Value

Configurable field; sets the value that triggers the alarm.

Detected Value

Read-only field; displays the last measurement made.

Rising Event

Configurable field; displays the response to a triggered
rising event.

partitionport — partitions the target port.

sendtrap — sends a trap to the receiving trap

station.

partitionportANDsendtrap — partitions the tar-

get port and sends a trap.

sendtrapANDrequestpage — sends a trap and

sends a page to the network administrator (if the
trap receiving station is an AsantéView Manage-
ment Station).

partitionportANDsendtrapANDrequestpage

— partitions the target port, sends a trap, and
send a page to the network administrator (if the
trap receiving station is an AsantéView Manage-
ment Station).

Falling Event

Configurable field; displays the response to a triggered
falling event. Options are the same as those for a rising
event (see “Rising Event” above).

Sample Interval

Configurable field; sets (in seconds) the polling interval.

Note: The shorter this time period, the more traffic on
the network.