Menus
Page 5-16
Field
Description
Startup Event
Configurable field; determines when the alarm is to be
triggered.
❏
rising — alarm is triggered when the event rate
rises above the threshold.
❏
falling — alarm is triggered when the event rate
falls below the threshold.
❏
rising and falling — alarm is triggered when the
event rate rises above or falls below the thresh-
old.
Threshold Value
Configurable field; sets the value that triggers the alarm.
Detected Value
Read-only field; displays the last measurement made.
Rising Event
Configurable field; displays the response to a triggered
rising event.
❏
partitionport — partitions the target port.
❏
sendtrap — sends a trap to the receiving trap
station.
❏
partitionportANDsendtrap — partitions the tar-
get port and sends a trap.
❏
sendtrapANDrequestpage — sends a trap and
sends a page to the network administrator (if the
trap receiving station is an AsantéView Manage-
ment Station).
❏
partitionportANDsendtrapANDrequestpage
— partitions the target port, sends a trap, and
send a page to the network administrator (if the
trap receiving station is an AsantéView Manage-
ment Station).
Falling Event
Configurable field; displays the response to a triggered
falling event. Options are the same as those for a rising
event (see “Rising Event” above).
Sample Interval
Configurable field; sets (in seconds) the polling interval.
Note: The shorter this time period, the more traffic on
the network.