Threshold – Asante Technologies Asante Hub 1016-IQ User Manual
Page 60

Menus
Page 5-14
Threshold
This menu displays the current alarms that are set and allows alarms to 
be added or modified. 
Alarms can help you locate problems or faults on the network. When 
you set an alarm threshold for an activity on a hub, you instruct the hub 
to take a specific action when the value falls above or below the set 
threshold.
Table 5-11 describes each field in the Threshold menu.
∆
Note: For instructions on using this menu, see “Setting 
Alarms” on page 4-18.
Table 5-11 Threshold Menu
Field
Description
Index
Read-only field; displays the number of the alarm entry. 
This field cannot be modified.
Status
Configurable field; displays the status of the entry in the 
table.
❏
valid — active entry.
❏
invalid — inactive entry (deletes the entry when
selected).
Target Domain
Configurable field; determines the portion of the device 
for which alarms are being set.
❏
hub — sets the alarm for the entire device.
❏
port — sets the alarm for a specific port; you
must enter the port number in the TPort field and 
the port’s group number in the TGroup field.
❏
group — sets the alarm for a specific group; you
must enter the group number in the TGroup 
field.
TGroup (target 
group)
Configurable field; determines the group number for 
which the alarm is being set. 
Important:  This field only needs to be edited if the Tar-
get Domain is set to group.