Threshold

Page 5-15

Field

Description

TPort (target port)

Configurable field; determines the port number for which
the alarm is being set.

Important: This field only needs to be edited if the Tar-
get Domain is set to port.

Target Subject

Configurable field; determines the counter to be polled.

readableframes — the total number of good or

readable frames (frames without error).

frametoolong — the number of frames that

were longer than 1,518 bytes.

runts — the number of frames that were shorter

than 64 bytes.

alignmenterrors — the number of frames that

were an integral number of octets in length and
did not pass the FCS check.

fcserrors — the number of frames that failed

Cyclic Redundancy Check (CRC).

dataratemismatch — the number of errors

where the incoming data rate is not within the
tolerance level of 10Mhz (+ or - 0.01%).

shortevents — the number of data bursts,

where data is less than 10 bytes in length.

collisions — the total number of collisions.

latecollisions — the number of collisions that

occurred after the 64-byte collision window.

autopartitions — the number of times the port

was automatically partitioned in response to 31
or more continuous collisions.

badframes — the number of invalid frames

(including toolong, runts, misaligned, or bad FCS).

Sample Type

Read-only field; sets a unit of measure for the alarm.

Note: This field is always set to eventpersecond and
cannot be modified.