Asante Technologies Asante Hub 1016-IQ User Manual
Page 53

Ports
Page 5-7
Field
Description
Jabber Status
Read-only field; displays the status of the Jabber Detec-
tor.
Note: A Jabber Detector is a device that helps prevent a
node from transmitting constantly; for example, if the
node is malfunctioning.
❏
on — jabber detector is on.
❏
off — jabber detector is off.
Jabber State
Configurable field; enables or disables the jabber detec-
tion test.
Polarity Status
Read-only field; displays the status of the auto polarity
check.
❏
normal — the auto polarity checking is enabled
and the polarity status is normal.
❏
reversed — the auto polarity checking is enabled
and the polarity status is reversed.
Polarity State
Configurable field; determines the state of the device’s
auto polarity correction.
Auto polarity correction allows a hub to make electrical
corrections automatically if a cable does not reverse
polarity within its pairs.
Admin State
Configurable field; determines the state of the port.
❏
enabled — the port is enabled and can receive
packets.
❏
disabled — the port is disabled and cannot
receive packets.