Parameter

Min

Max

Unit

IDMA Read, Long Read Cycle

Timing Requirements:
t

IKR

IACK

Low before Start of Read

1

0

ns

t

IRP

Duration of Read

15

ns

Switching Characteristics:
t

IKHR

IACK

High after Start of Read

1

15

ns

t

IKDS

IAD15–0 Data Setup before IACK Low

0.5t

CK

–10

ns

t

IKDH

IAD15–0 Data Hold after End of Read

2

0

ns

t

IKDD

IAD15–0 Data Disabled after End of Read

2

10

ns

t

IRDE

IAD15–0 Previous Data Enabled after Start of Read

0

ns

t

IRDV

IAD15–0 Previous Data Valid after Start of Read

15

ns

t

IRDH1

IAD15–0 Previous Data Hold after Start of Read (DM/PM1)

3

2t

CK

–5

ns

t

IRDH2

IAD15–0 Previous Data Hold after Start of Read (PM2)

4

t

CK

–5

ns

ADSP-2183

28.8 MHz

Parameter

Min

Max

Unit

IDMA Read, Long Read Cycle

Timing Requirements:
t

IKR

IACK

Low before Start of Read

1

0

ns

t

IRP

Duration of Read

15

ns

Switching Characteristics:
t

IKHR

IACK

High after Start of Read

1

17

ns

t

IKDS

IAD15–0 Data Setup before IACK Low

0.5t

CK

–10

ns

t

IKDH

IAD15–0 Data Hold after End of Read

2

0

ns

t

IKDD

IAD15–0 Data Disabled after End of Read

2

10

ns

t

IRDE

IAD15–0 Previous Data Enabled after Start of Read

0

ns

t

IRDV

IAD15–0 Previous Data Valid after Start of Read

15

ns

t

IRDH1

IAD15–0 Previous Data Hold after Start of Read (DM/PM1)

3

2t

CK

–5

ns

t

IRDH2

IAD15–0 Previous Data Hold after Start of Read (PM2)

4

t

CK

–5

ns

NOTES

1

Start of Read = IS Low and IRD Low.

2

End of Read = IS High or IRD High.

3

DM read or first half of PM read.

4

Second half of PM read.

t

IRP

t

IKR

PREVIOUS

DATA

READ
DATA

t

IKHR

t

IKDS

t

IRDV

t

IRDH

t

IKDD

t

IRDE

t

IKDH

IAD 15–0

IACK

IS

IRD

Figure 31. IDMA Read, Long Read Cycle