ADSP-2181

Parameter

Min

Max

Unit

Memory Read

Timing Requirements:
t

RDD

RD

Low to Data Valid

0.5t

CK

– 9 + w

ns

t

AA

A0-A13, xMS to Data Valid

0.75t

CK

– 10.5 + w

ns

t

RDH

Data Hold from RD High

0

ns

Switching Characteristics:
t

RP

RD

Pulse Width

0.5t

CK

– 5 + w

ns

t

CRD

CLKOUT High to RD Low

0.25t

CK

– 5

0.25t

CK

+ 7

ns

t

ASR

A0-A13, xMS Setup before RD Low

0.25t

CK

– 6

ns

t

RDA

A0-A13, xMS Hold after RD Deasserted

0.25t

CK

– 3

ns

t

RWR

RD

High to RD or WR Low

0.5t

CK

– 5

ns

ADSP-2183

28.8 MHz

Parameter

Min

Max

Unit

Memory Read

Timing Requirements:
t

RDD

RD

Low to Data Valid

0.5t

CK

– 9 + w

ns

t

AA

A0-A13, xMS to Data Valid

0.75t

CK

– 12.5 + w

ns

t

RDH

Data Hold from RD High

0

ns

Switching Characteristics:
t

RP

RD

Pulse Width

0.5t

CK

– 5 + w

ns

t

CRD

CLKOUT High to RD Low

0.25t

CK

– 5

0.25t

CK

+ 7

ns

t

ASR

A0-A13, xMS Setup before RD Low

0.25t

CK

– 6

ns

t

RDA

A0-A13, xMS Hold after RD Deasserted

0.25t

CK

– 3

ns

t

RWR

RD

High to RD or WR Low

0.5t

CK

– 5

ns

w = wait states x t

CK

xMS

= PMS, DMS, CMS, IOMS, BMS

CLKOUT

A0 – A13

D

t

RDA

t

RWR

t

RP

t

ASR

t

CRD

t

RDD

t

AA

t

RDH

DMS

,

PMS,

BMS

,

IOMS,

CMS

RD

WR

Figure 25. Memory Read