beautypg.com

Adsp-2181, Adsp-2183 – Analog Devices ADSP-2181 User Manual

Page 28

background image

ADSP-2181/ADSP-2183

REV. 0

–28–

ADSP-2181

Parameter

Min

Max

Unit

IDMA Write, Long Write Cycle

Timing Requirements:
t

IKW

IACK

Low before Start of Write

1

0

ns

t

IKSU

IAD15–0 Data Setup before IACK Low

2, 3

0.5t

CK

+ 10

ns

t

IKH

IAD15–0 Data Hold after IACK Low

2, 3

2

ns

Switching Characteristics:
t

IKLW

Start of Write to IACK Low

4

1.5t

CK

ns

t

IKHW

Start of Write to IACK High

15

ns

ADSP-2183

28.8 MHz

Parameter

Min

Max

Unit

IDMA Write, Long Write Cycle

Timing Requirements:
t

IKW

IACK

Low before Start of Write

1

0

ns

t

IKSU

IAD15–0 Data Setup before IACK Low

2, 3

0.5t

CK

+ 10

ns

t

IKH

IAD15–0 Data Hold after IACK Low

2, 3

2

ns

Switching Characteristics:
t

IKLW

Start of Write to IACK Low

4

1.5t

CK

ns

t

IKHW

Start of Write to IACK High

17

ns

NOTES

1

Start of Write = IS Low and IWR Low.

2

If Write Pulse ends before IACK Low, use specifications t

IDSU

, t

IDH

.

3

If Write Pulse ends after IACK Low, use specifications t

IKSU

, t

IKH

.

4

This is the earliest time for IACK Low from Start of Write. For IDMA Write cycle relationships, please refer to the User’s Manual.

IAD 15–0

DATA

t

IKHW

t

IKW

IACK

IS

IWR

t

IKLW

t

IKH

t

IKSU

Figure 30. IDMA Write, Long Write Cycle