beautypg.com

Adsp-2181, Adsp-2183 – Analog Devices ADSP-2181 User Manual

Page 27

background image

ADSP-2181/ADSP-2183

REV. 0

–27–

ADSP-2181

Parameter

Min

Max

Unit

IDMA Write, Short Write Cycle

Timing Requirements:
t

IKW

IACK

Low before Start of Write

1

0

ns

t

IWP

Duration of Write

1, 2

15

ns

t

IDSU

IAD15–0 Data Setup before End of Write

2, 3, 4

5

ns

t

IDH

IAD15–0 Data Hold after End of Write

2, 3, 4

2

ns

Switching Characteristics:
t

IKHW

Start of Write to IACK High

15

ns

ADSP-2183

28.8 MHz

Parameter

Min

Max

Unit

IDMA Write, Short Write Cycle

Timing Requirements:
t

IKW

IACK

Low before Start of Write

1

0

ns

t

IWP

Duration of Write

1, 2

15

ns

t

IDSU

IAD15–0 Data Setup before End of Write

2, 3, 4

5

ns

t

IDH

IAD15–0 Data Hold after End of Write

2, 3, 4

2

ns

Switching Characteristics:
t

IKHW

Start of Write to IACK High

17

ns

NOTES

1

Start of Write = IS Low and IWR Low.

2

End of Write = IS High or IWR High.

3

If Write Pulse ends before IACK Low, use specifications t

IDSU

, t

IDH

.

4

If Write Pulse ends after IACK Low, use specifications t

IKSU

, t

IKH

.

IAD 15–0

DATA

t

IKHW

t

IKW

t

IDSU

IACK

t

IWP

t

IDH

IS

IWR

Figure 29. IDMA Write, Short Write Cycle

This manual is related to the following products: