Esc i l apply/cancel rotated printing, Esc i c specify cut setting – Brother PT-9700PC User Manual
Page 68
68
ESC i L Apply/cancel rotated printing
[ASCII] ESC i L n
[Decimal]
27 105 76 n
[Hexadecimal]
1B 69 4C n
[Parameters]
n=0 and 1 or 48 and 49
[Description]
・
Applies rotated printing to the text.
If n=0 (or 30h), rotated printing is cancelled.
If n=1 (or 31h), rotated printing is applied.
ESC i C Specify cut setting
[ASCII] ESC i C n
[Decimal]
27 105 67 n
[Hexadecimal]
1B 69 43 n
[Parameters] 0≤n≤255
[Description]
・
Specifies full cut, half cut, chain printing or special tape.
・
The n parameter (1 byte) specifies all settings in bit units, as shown below.
7 6 5 4 3 2 1 0
0: Full cut
1: Half cut
2: Chain printing
3: Special tape
4: Not used
5: Not used
6: Not used
7: Not used
・
If bit 0 of parameter n is “1”, full cut is specified. If it is “0”, full cut is cancelled.
・
If bit 1 of parameter n is “1”, half cut is specified. If it is “0”, half cut is cancelled.
・
If bit 2 of parameter n is “1”, chain printing is applied. If it is “0”, chain printing is
cancelled.
・
If bit 3 of parameter n is “1”, special tape is specified. If it is “0”, special tape is
cancelled.
When special tape is specified, full cut, half cut and chain printing are not available
(same as being cancelled).