beautypg.com

Brother PT-9700PC User Manual

Page 59

background image

59

characters that can be entered may decrease, depending on the characters that are used.

2 When the symbol type is the structured carrier message, the service class, country

code and postal code can be specified separately from the normal data. Specify each

value, separated by a backslash and comma (\,), immediately before the normal data.

<postal_code>\,<country_code>\,<service_class>\,<normal_bar_code_data>

When “\,” is not used three times, the data is written as shown in the following

example.

Example <data1>\,<data2>\,<normal_bar_code_data>

Postal code = data1

Country code = data2

Service class = default value

If a value other than those listed is entered for a parameter, that parameter is set to its

default value.

Postal code
9 or less numerals, or 6 or
less alphanumeric characters

Ignored when not structured carrier message.
Default value: 000000000

Country code

3 or less numerals

Ignored when not structured carrier message.
Default value: 000

Service class

3 or less numerals

Ignored when not structured carrier message.
Default value: 000

* Note:

If the postal code is specified as alphanumeric characters, characters other than

those listed below are invalid.

A~Z “ # $ % & ‘ ( ) * + , - . / 0~9 :

However, lowercase letters (a~z) are converted to the valid uppercase letters (A~Z).

④ \\\: End of bar code

There must be three backslashes at the end of 2D bar codes.

This manual is related to the following products: