Alarms based on LPR
o
Time limit: Lets you select a time limit for when operator action is required. Default setting
is 1 minute. The time limit is not active before an event is attached.
o
Events triggered: Lets you select which event to trigger when the time limit has been
reached.
Choose additional settings:
o
Related cameras: Lets you select (a maximum of 15) cameras for inclusion in the LPR
alarm definition (note that they do not trigger the alarm themselves).
o
Related map: Lets you assign a map to the LPR alarm when it is listed in the XProtect
Smart Client's Alarm Manager.
o
Initial alarm owner: Lets you select a default user responsible for the LPR alarm.
o
Initial alarm priority: Lets you select a priority (High, Medium or Low) for the LPR alarm.
Priorities can be used for sorting purposes and workflow control in the XProtect Smart
Client.
o
Initial Alarm Category: Lets you select an alarm category for the LPR alarm. This could
be for example False alarm or Needs investigation.
o
Event triggered by alarm: Lets you define an event to be triggered by the LPR alarm in
the XProtect Smart Client (if needed).
Tip: If you want to disable the new alarm from the beginning, clear the Enable check box in the upper
left corner before saving.