Ramp / Soak Operation
When you wish to start the program, enter the Secondary Menu and set the Prog menu item to On.
Return to the HOME position by waiting for the display to time out or by pressing the UP ARROW /
ENTER keys and then the DOWN ARROW / INDEX keys.
The home display will read as it normally does. The HOLD indicator over the RUN / HOLD key will be
lit. To start the program press INDEX to display Prog. Press the UP ARROW key to select run and
press ENTER. The HOLD indicator will go out, and the program will start.
To suspend the program at any time, INDEX to Prog, press the DOWN ARROW key to display HOLd,
and press ENTER. To resume, INDEX to Prog, press the UP ARROW to select run, and press ENTER.
Entering the AUTO / MANUAL mode will also suspend the program operation. The difference is that
AUTO / MANUAL also puts the control into manual mode. See Auto / Manual Operation.
The function of the Primary Menu will change depending on the setting of the StAt menu item in the
Secondary Menu. If StAt is OFF then the Primary Menu is not changed.
If the StAt menu item is set to On, then the Primary Menu has three additional information items added
before SP1 appears. The first INDEX item, ####/ ti, displays the time remaining in the current seg-
ment. The next INDEX item, ####/##ti, displays the total time for the active segment (1ti...16ti). The
third INDEX item, ####/##SP, displays the segment set value (1SP...16SP). The next INDEX press
resumes the normal Primary Menu.