Badger Meter Turbine Flow Meters (Hydraulic Fluids) User Manual
Page 8

Turbine Flow Sensor
Installation & Operating Instructions
Page 8
03/12 Form No. 05-TUR-UM-00194
Quad Flow Sensors
Material
Housing:
6013-T651 Anodized aluminum
Turbine Rotor:
T416 Stainless steel
Rotor Supports:
6061-T6 Aluminum
Rotor Shaft:
T303 Stainless steel
Bearings:
440 C Stainless steel ball bearings
Hub Cones:
6061-T6 Aluminum alloy
Retaining Rings:
Steel, zinc plate
Seals:
Buna N standard
Viton® and EPR optional
Magnetic Pick-up:
Body
T303 Stainless Steel
Nut
T303 Stainless Steel
Ports:
SAE Straight thread O-ring boss, female, J1926/1;
Dimensions
See Appendix, page 16
Model Number Information
Performance
Flow Accuracy:
±1% of full scale
Repeatability: ±0.2%
Pressure Rating:
5000 PSI (345 Bar) maximum,
Pressure Drop:
See ∆ P charts on page 17
Turbine Response:
≤200 ms
Fluid Temperature:
-4 to +300 °F (-20 to +150 °C)
Ambient Temperature:
-4 to +131 °F (-20 to +55 °C)
Electrical
Magnetic Pick-up:
Self-generating alternating pulse;
100 mV RMS (100 Hz) minimum.
Calibration
Flow sensors are calibrated with 0.876 specific gravity, 140
SUS (32 cSt) hydraulic oil. Standard calibration is done using
3-points and is traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-
STD 45662A.
Nominal
Port Size
Flow Rate
Series
Model
SAE 12
1 - 15 GPM
FSC-2005
F2082-ASCQ4
SAE 12
2 - 25 GPM
FSC-2075
F2083-ASCQ4
SAE 16
3 - 60 GPM
FSC-2100
F2084-ASCQ4
SAE 16
4 - 85 GPM
FSC-2150
F2085-ASCQ4