III. SPECIFICATIONS
Activa™ and Ultima Sensor Arrays
Material
Housing:
6013-T651 Anodized aluminum
Turbine Rotor:
T416 Stainless steel
Rotor Supports:
6061-T6 Aluminum,
C360 Brass for ¼" models
Rotor Shaft:
T303 Stainless steel
Ball Bearings:
440 C Stainless steel
Hub Cones:
6061-T6 Aluminum alloy
Retaining Rings:
6061-T6 Aluminum alloy
Adapters/Plugs:
6061-T6 Anodized aluminum
Seals:
Buna N standard
Viton® and EPR optional
Magnetic Pick-up:
Body
T303 Stainless Steel
Nut
T303 Stainless Steel
IFC (Intelligent Frequency Converter), Activa only:
Body
6061-T6 Aluminum, nickel plate
Connector
Brass, nickel plate
Temperature Probe:
12L14 Steel, electroless nickel finish
Pressure Sensor:
Case
300 Series stainless steel
Diaphragm
17-4 PH stainless steel
Ports:
SAE Straight thread O-ring boss, female, J1926/1;
ISO1179 (BSPP)
Dimensions
See Appendix, page 16
Model Number Information
Performance
Flow Accuracy:
Activa
±1% of reading @ 32 cSt
Ultima
±1% of full scale
Repeatability: ±0.2%
Pressure Rating:
5800 PSI (400 Bar) maximum,
5000 PSI (345 Bar) maximum for 1-¼" models
Pressure Drop:
See ∆ P charts on page 17
Turbine Response:
≤200 ms
Fluid Temperature:
-4 to +300 °F (-20 to +150 °C)
Ambient Temperature:
-4 to +131 °F (-20 to +55 °C)
Electrical
Activa
4-20 mA
0-5 VDC
Power:
Loop-powered, 6V
10-26 VDC
insertion loss max
10-30 VDC supply
Inputs:
Mag pick-up
Mag pick-up
Frequency
0-3500 Hz
0-3500 Hz
Trigger
Sensitivity
30 mV p-p
30 mV p-p
Freq Meas Accuracy
±1%
±1%
Analog Out:
4-20 mA current loop
0-5 VDC
Resolution
1:4000
1:4000
Temp Drift
50 ppm/°C max
50 ppm/°C max
Environmental:
Ambient Temp
-22 to +158 °F
-22 to +158 °F
(-30 to +70 °C)
(-30 to +70 °C)
Humidity
0-90%
0-90%
non-condensing non-condensing
Ultima
Magnetic Pick-up:
Self-generating alternating pulse;
100 mV RMS (100 Hz) minimum.
F6202 & F6222 only
10 mV RMS (200Hz) minimum
Calibration
Flow sensors are calibrated with 0.876 specific gravity, 140
SUS (32 cSt) hydraulic oil. Standard calibration is done using
3-points and is traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-
STD 45662A.
Nominal
Port Size
Flow Rate
Model
IFC Converter
or Mag Pick-up
Seals
Sensor Ports
Temperature
Pressure
SAE 8
0.4 - 7 GPM
F6202
Activa Models:
AI 4-20 mA Out
AV 0-5 VDC Out
Ultima Models:
F Frequency Out
B Buna N
V Viton
E EPR
T with Sensor
N ¼ NPT(F)
Plugged
S SAE 2 Plugged
G G ¼ Plugged
D SAE 4 Plugged
1 1000 PSI
3 3000 PSI
5 5000 PSI
6 6000 PSI *
N ¼ NPT(F)
Plugged
S SAE 2 Plugged
F G ¼ Plugged
* Not available with
Models F6208 or F6228
SAE 12
2 - 40 GPM
F6204
SAE 16
4 - 80 GPM
F6206
SAE 20
8 - 160 GPM
F6208
G ¼
1.5 - 26 LPM
F6222
G ¾
7.5 - 151 LPM
F6224
G 1
15 - 302 LPM
F6226
G 1-¼
30 - 605 LPM
F6228
Examples:
F6204-AIB-T6
= SAE 12 ports, 2-40 GPM flow range
Buna N seals, Temperature sensor
6000 PSI (414 Bar) pressure sensor
F6208-FV-TN
= SAE 20 ports, 8-160 GPM flow range
Viton seals, Temperature sensor
1/4 NPT (F) plugged pressure port