Wiring
Typical wiring configurations for the available pickup options are shown in
Option Number
Description
Number of Pins
0
NEMA 6 – Magnetic
3
1
NEMA 6 – Magnetic (Amplified)
3
2
Non-NEMA 6 – Magnetic
2
3
Non-NEMA 6 – Magnetic (Amplified)
3
4
Non-NEMA 6 – Active (4…20 mA)
5
6
Non-NEMA 6 – Magnetic (High Temperature)
2
8
Non-NEMA 6 – Active (0…5V DC)
5
9
No Pickup
N/A
Table 3: Pickup options
Pickup Option 1
Braided Shield to
Earth Ground
3 - Red/White = Signal
2 - Red/Black = Power
1 - Green = Common
Mag Pickup
With Pre-Amp
(Socket End)
1. Common:
Power return
2. Power:
12…24 Vdc
3. Output Signal: 10V DC Square Wave
Pins
Pickup Option 0
Braided Shield to
Earth Ground
3 - Red/White = Unused
2 - Red/Black = Signal
1 - Green = Signal
Standard
Mag Pickup
(Socket End)
1. Signal
2. Signal
3. Unused
Pins
Figure 5: Wiring for NEMA 6 magnetic pickups
User Manual
Page 9
November 2013
- BEACON Advanced Metering Analytics (AMA) (2 pages)
- GALAXY (16 pages)
- GALAXY (20 pages)
- GALAXY (28 pages)
- ORION Cellular Endpoint (2 pages)
- ORION Cellular Endpoint (32 pages)
- ORION Cellular Endpoint (80 pages)
- ORION Migratable (ME) (96 pages)
- ORION Migratable (ME) (72 pages)
- ORION Migratable (ME) (60 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (28 pages)
- ORION Classic (CE) (8 pages)
- ORION Classic (CE) (16 pages)
- ORION Classic (CE) (32 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (28 pages)
- ORION Fixed Network (SE) (4 pages)
- ORION Fixed Network (SE) (48 pages)
- ORION Migratable (ME) (48 pages)
- ORION Migratable (ME) (2 pages)
- ORION Migratable (ME) (32 pages)
- ORION Migratable (ME) (20 pages)
- E-Series Ultrasonic Meters (2 pages)
- E-Series Ultrasonic Meters (12 pages)
- M-Series M2000 (24 pages)
- M-Series M2000 (2 pages)
- M-Series M2000 (4 pages)
- M-Series M2000 (60 pages)
- M-Series M3000 (40 pages)
- M-Series M4000 (36 pages)
- M-Series M5000 (36 pages)
- M-Series M5000 (4 pages)
- M-Series Field Verification Device (24 pages)
- Recordall Disc Series Meters (4 pages)
- Recordall Turbo Series Meters (20 pages)
- Recordall Transmitter Register (RTR) (2 pages)
- Industrial Turbo (16 pages)
- Water Conditioning (16 pages)
- Recordall Compound Series Meters (2 pages)
- Recordall Compound Series Meters (20 pages)
- Recordall Compound Series Meters (16 pages)
- Remote Electronic Display (RED) (8 pages)