Specifications – Badger Meter M-Series M3000 User Manual
Page 30

30
SPECIFICATIONS
Flow Range: 0.1 to 39.4 ft/s (0.03 – 12 m/s)
Flow Direction: Uni-directional or Bi-directional
Sizes: 1/4" to 24" (6 to 600mm)
Conductivity: Min. 5 micromhos/cm
Accuracy: ± 0.25% of rate for velocities greater than 1.64 ft/s
(0.50
m/s)
± 0.004 ft/s (± 0.001) m/s) for velocities less than
1.64 ft/s (0.50 m/s)
Electrode Materials: Alloy C, 316 stainless steel, gold/platinum plated,
tantalum, platinum/rhodium
Liner Material: PFA from 1/4” to 3/8" (6 to 10mm), PTFE from 1/2" to
24" (15 to 600mm), soft and hard rubber from 1" to 24" (25 to 600mm),
Halar
®
from 12" (300mm) to 24" (600mm)
NSF Listed:
Models with hard rubber liner, 4-inch and larger
PTFE liner - all sizes
Fluid Temperature:
With remote mounted amplifi er
PFA, PTFE & Halar: -4°F to 248°F (-20°C to
120°C) @ Max. ambient temp. of 122°F (50°C)
Soft & Hard rubber: 32°F to 178°F (0°C to 80°C)
@ Max. ambient temp. of 122°F (50°C)
With meter mounted amplifi er
PFA, PTFE, & Halar: -4°F to 212°F (-20°C to 100°C) @
Max. ambient temp. of 122°F (50°C)
Soft & hard rubber: 32°F to 178°F (0°C to 80°C)
@ Max. ambient temp. of 122°F (50°C)
Coil Power: Pulsed DC
Pipe Spool Material: 316 stainless steel
Spool Housing Material: Carbon steel, welded - NEMA 4X/6P (IP66/
IP67). Tested at 1.8m (6 feet) for 24 hours.
Junction Enclosure Material: (for remote mounted amplifi er option)
Cast Aluminum (powder coated paint), NEMA 4X/6P (IP66/IP67). Tested
at 1.8m (6 feet) for 24 hours.
Flanges: Carbon Steel or 316 stainless steel (ANSI B16.5 Class 150 RF)
Grounding Rings (optional, 2 required) : 316 stainless steel
Meter Size
Thickness (one ring)
1/4" to 10" (6 to 250mm)
.135" (3.43mm)
10" to 24" (250 to 600mm)
.187" (4.75mm)
Grounding Electrode (optional): Alloy C, 316 stainless steel, gold/plati-
num plated, tantalum, or platinum/rhodium
Electrical Classifi cation: FM approved for Class I, Div 2 Groups A-D,
Class II, Div 2 Groups F&G - CSA Certifi ed
Pressure Limits: Max. 150 psi (10 bar)
Ambient Temperature: -4°F to 122°F (-20°C to 50°C)
Locations: Indoor and outdoor
Altitude: Maximum 6500 feet (2000m)
M-3000 Meter Mount Amplifi er on Detector
M-3000 Remote Mount Junction Box on Detector
7.52"
191mm
5.20"
132mm
7.22"
183mm
B
A
9.20"
234mm
5.47"
139mm
3.73"
95mm
3.54"
90mm
4.25"
108mm
0 C
SIZE
7.42"
188m
B
A
8