CONFIGURING INPUT/OUTPUT (I/O)
This section describes wiring the following M5000 outputs:
•
Digital outputs
•
Communication
When the sensor and the amplifier have been wired, wire any outputs to the M5000 amplifier .
Follow all of the safety precautions and local code to prevent electrical shock and damage to the electronic components .
Circuit Board Diagram
Figure 21: Configuring Input/Output
Input/Output
Description
Terminal
Output 1
Passive max . 30V DC, 20 mA
Max . Frequency 100 Hz
OUT1 (+) and (–)
Output 2
Passive max . 30V DC, 20 mA
Max . Frequency 100 Hz
OUT2 (+) and (–)
Output 3
Passive Max 30V DC, 20 mA
OUT3 (+) and (–)
Output 4
Passive Max 30V DC, 20 mA
Can be used with digital input as an ADE interface .
OUT4 (+) and (–)
RS232
Modbus RTU
RxD, TxD, GND
IN
Digital input 3…35V DC
IN (+) and (–)
M-BUS
M-Bus interface
No polarity
Configuring input/output (i/o)
MAG-UM-00219-EN-03
Page 16
August 2014
- BEACON Advanced Metering Analytics (AMA) (2 pages)
- GALAXY (16 pages)
- GALAXY (20 pages)
- GALAXY (28 pages)
- ORION Cellular Endpoint (2 pages)
- ORION Cellular Endpoint (32 pages)
- ORION Cellular Endpoint (80 pages)
- ORION Migratable (ME) (96 pages)
- ORION Migratable (ME) (72 pages)
- ORION Migratable (ME) (60 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (28 pages)
- ORION Classic (CE) (8 pages)
- ORION Classic (CE) (16 pages)
- ORION Classic (CE) (32 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (28 pages)
- ORION Fixed Network (SE) (4 pages)
- ORION Fixed Network (SE) (48 pages)
- ORION Migratable (ME) (48 pages)
- ORION Migratable (ME) (2 pages)
- ORION Migratable (ME) (32 pages)
- ORION Migratable (ME) (20 pages)
- E-Series Ultrasonic Meters (2 pages)
- E-Series Ultrasonic Meters (12 pages)
- M-Series M2000 (24 pages)
- M-Series M2000 (2 pages)
- M-Series M2000 (4 pages)
- M-Series M2000 (60 pages)
- M-Series M3000 (40 pages)
- M-Series M4000 (36 pages)
- M-Series M5000 (4 pages)
- M-Series Field Verification Device (24 pages)
- Recordall Disc Series Meters (4 pages)
- Recordall Turbo Series Meters (20 pages)
- Recordall Transmitter Register (RTR) (2 pages)
- Industrial Turbo (16 pages)
- Water Conditioning (16 pages)
- Recordall Compound Series Meters (2 pages)
- Recordall Compound Series Meters (20 pages)
- Recordall Compound Series Meters (16 pages)
- Remote Electronic Display (RED) (8 pages)