Parameter-level 41, 1 parameter-survey 41, 2 adjustment: 41 – West Control Solutions SG 45 User Manual
Page 41: Parameter-survey 41, Di.fn, Err.r, Tara, Hold, Res.l
![background image](/manuals/370846/41/background.png)
Signal definition LOGI
Name
Value range
Description
di.Fn
Function of inputs (valid for all inputs)
0
direct
1
inverse
2
toggle key function (adjustable for 2-point-operation with interface and di1)
L_r
Local / remote switchover
(Remote: Adjustment of all values via the front panel is blocked)
0
Interface only (local, value adjustment via front-panel controls is possible)
1
always active (remote)
2
di1 switches
7
Limit 1 switches
8
Limit 2 switches
9
Limit 3 switches
Err.r
Resetting of all stored entrys of the error list
0
Interface only
2
di1 switches
7
Limit 1 switches
8
Limit 2 switches
9
Limit 3 switches
10
Enter/Inc keys switch Ü
11
Enter/Dec key switch Ü
tArA
Tare-function (Function must be akctivated (CONF /FUNC / Fnc.2= 3))
0
Interface only
2
di1 switches
7
Limit 1 switches
8
Limit 2 switches
9
Limit 3 switches
10
Enter/Inc keys switch Ü
11
Enter/Dec key switch Ü
HoLd
Sample & Hold-Fctn. (Function must be akctivated (CONF /FUNC / Fnc.2 = 2))
0
Interface only
2
di1 switches
7
Limit 1 switches
8
Limit 2 switches
9
Limit 3 switches
10
Enter/Inc keys switch Ü
11
Enter/Dec key switch Ü
rES.L
Reset minimum value
0
Interface only
2
di1 switches
7
Limit 1 switches
8
Limit 2 switches
9
Limit 3 switches
10
Enter/Inc keys switch Ü
11
Enter/Dec key switch Ü
Configuration level
41
Configurations
SG 45