Electrical connections 11, 1 connecting diagram 11, 2 terminal connections 11 – West Control Solutions SG 45 User Manual
Page 11: Inp1 11, Connecting diagram 11, 13, 4 electrical connections, Connecting diagram, Terminal connections
.
4
Electrical connections
4.1
Connecting diagram
4.2
Terminal connections
a
Faulty connection might cause destruction of the instrument !
1 Connecting the supply voltage
Dependent on order
•
90 … 260 V AC
terminals: 15,16
•
24 V AC / DC
terminals: 15,16
For further information, see section
"Technical data"
g
Instruments with optional system interface:
Energization is via the bus connector of field bus coupler or power supply module. Terminals 15, 16 must
not be used.
2 Connecting input INP1
Input for strain gauge (in 4 and 6-wire connection) or for melt pressure sensors (with/without calibration shunt).
a
Excitation voltage for bridge (EXITATION )
terminals: 1, 4
b
Excitation voltage measuring signal (Sense)
terminals: 2, 3
c
Bridge signal (input)
terminals: 5, 6
Electrical connections
SG 45
Connecting diagram
11
Data A
Data A
Data B
Data B
OUT3
PWR
OUT1
OUT2
di1
RGND
RGND
RS 485
1
INP1
2
3
4
5
6
a
c
b
d
e
11 12 13 14
11 12 13 14
15 16 17 18
15 16 17 18
1 2 3 4
1 2 3 4
top
14
13
12
16
15
11
17 18
L
N
~90-260V
~24V
V
16
15
17 18
System
8
7
6
3
2
1
5
3
4
INP
+
-
EX +
EX -
+ Sense -