beautypg.com

C sil-2 features, Sil-2 features, Csil-2 features – Spectrex Quasar 900 Open-Path Gas Detection System User Manual

Page 69

background image

Safety Relevant Parameters for the Quasar 900 Open Path Gas Detector

57

C

SIL-2 Features

In this appendix…

Safety Relevant Parameters for the Quasar
900 Open Path Gas Detector

page 57

General Conditions for Safe Use

page 58

This appendix details the special conditions to comply with the requirements
of EN 61508 for SIL-2.

The SafEye Quasar 900 IR Open-Path Gas Detector can be used in low and
high demand mode applications, see IEC 61508-4:2010, Chapter 3.5.16.

C.1

Safety Relevant Parameters for the Quasar
900 Open Path Gas Detector

Type:

B

Structure:

1oo1

HFT:

0

Main time to repair:

72 h

Ambient temperature: max. 65°C

Proof-Test-Interval:

52 weeks

DC = 94%

PFD

avg

= 6.45x 10

-4

PFD

%_SIL2

= 6,4 %

PFH = 1.15 x 10

-7

1/h

PFH

%_SIL2

= 11,5 %

S

2056.1fit

D

1976.1fit

DU

114.8fit

SD

1933.4fit

DD

1861.4fit

SFF

97 %