2 visual indicators, 3 output signals, 1 0-20ma current output – Spectrex Quasar 900 Open-Path Gas Detection System User Manual
Page 27: Visual indicators, Output signals, 20ma current output, Table 3: detector led indications, Table 4: source led indications
TM 888200 Rev (I), January 2014
Visual Indicators
15
3.2
Visual Indicators
One 3-color LED indicator is located in the back side of the detector/source
and can be seen through the back cover window. See Figure 2 and
Figure 3, item 11.
The detector statuses are listed in Table 3.
Table 3: Detector LED Indications
Detector Status
LED Color
LED Mode
Fault
Yellow
4Hz – flashing
Alignment / Standby
Yellow
1Hz – flashing
Zero Calibration
Yellow
Constant
Normal
Green
1Hz – flashing
Warning
Red
2Hz – flashing
Alarm
Red
Steady
The source statuses are listed in Table 4.
Table 4: Source LED Indications
Source Status
LED Color
LED Mode
Fault
Yellow
4Hz – flashing
Normal
Green
1Hz – flashing
3.3
Output Signals
The SafEye system provides the following outputs:
0-20mA Current Output, page 15
RS-485 Interface, page 16
3.3.1 0-20mA Current Output
The 0-20mA output provides the detector status measurement showing a
continuous reading of exact gas concentration.
The 0-20mA functions as current sink, but it can be configured as Source
(see Appendix A).
The maximum permitted load resistance for the 0-20mA output is 600Ω.