beautypg.com

2 technical description, 1 features, Technical description – Spectrex Quasar 900 Open-Path Gas Detection System User Manual

Page 15: Features, 2technical description

background image

Features

3

2

Technical Description

In this chapter…

Features

page 3

Applications

page 4

Principle of Operation

page 4

Product Certification

page 7

Models and Types

page 8

Description

page 9

2.1

Features

Long Range Gas Detection up to 660ft (200m)

Simultaneous detection of C1-C8 flammable gases

High Sensitivity and fast response to Hydrocarbon gases

Heated optics to improve performance in icing, condensation and snow
conditions

Continuous operation in extreme and harsh environmental

Conditions

Solar blind and immune to industrial environments

Withstands extreme vibration conditions

Standard 0-20 mA Output

HART Protocol: Communication Protocol

RS-485 Output Modbus compatible for PC Communication Network for a
maximum of 247 systems

Simple one person installation, alignment, and calibration

ATEX & IECEx per EX II 2 GD, Ex d e ib [ib Gb] IIB+H2 T4 Gb, Ex tb IIIC
T135°C Db IP66

TUV approved per SIL2 requirements

FM / FMC approved per: Class I Div. 1 Group B, C and D; Class II/III
Div. 1 Group E, F and G

Functional approved per FM 6325

Functional tested by FM per EN60079-29-4

Programmable configuration via the handheld unit

Fast connection to I.S. approved handheld diagnostic/calibration unit

(3mA) “maintenance call”

Warranty 3 years for the complete SafEye system

Warranty 10 years for Xenon Flash bulb