6. Recording modes
List of recording modes
Recording
mode
Details
To check:
P.26
Condition,
Intermittent
leakage
P.27
Occurrence of
leakage
P.28
Intermittent
leakage,
Occurrence of
leakage
P.29
Waveform
Can record:
60,000 data(1ch)
20,000 data(3ch)
4,800 data(1ch)
1,600 data(3ch)
990 data(1ch)
330 data(3ch)
345 data
Available CH
3 channels at the same time
----
CH1 only
Recording
interval
15-kind:
1 sec. to 60 min.
0∼1000mA (can be set at every 1mA)
Pre-set
current value
----
Approx. 0.1 sec. (constant)
Current detection:
approx. 0.56mS
RMS:approx.
1.11mS
Measureme
nt interval
Pre-set recording
interval
(intermittent
measurement)
Current detection:
approx. 1.67mS
RMS:
approx. 3.33mS
Constantly until current detection
Sampling
cycle
At 50Hz:
approx. 0.222mS
At 60Hz:
approx. 0.185mS
Sampling
period
For 2 cycles
(50Hz: for 40mS)
When the pre-set current value is exceeded. (irregular)
Record
timing
At every recording
interval
Current detection:
Average value (Convert the Peak value (sine) to RMS)
Record/Display: True RMS
Measuring
method
True RMS
One-time
system
O N : Recording stops when memory becomes full.
OFF: Overwrite the old data, and store the latest data.
Battery life
Approx. 25 days (M-5000)/ Approx. 40 days (M-5001)
Continuous
recording
Event recording
Max. value
recording
Capture
recording