BM 102


Construction materials

Housing

Aluminium with epoxy coating

Probe

Refer to section 4.2.1: BM 102 mechanical options

Gasket

Viton, optionally Kalrez 6375

Spacers (on twin probes)

Refer to section 4.2.1: BM 102 mechanical options


Weight

Housing

2 kg or 4.4 lb

Single rod Ø8mm or Ø0.3”

0.41 kg/m or 0.28 lb/ft

Single cable Ø4mm or Ø0.15” 0,12 kg/m or 0.08 lb/ft
Twin cable Ø4mm or Ø0.15”

0.24 kg/m or 0.16 lb/ft

Single cable Ø8mm or Ø0.3”

0.41 kg/m or 0.28 lb/ft

Coaxial Ø28mm or Ø1.1”

1,3 kg/m or 0.87 lb/ft

Standards


The level gauge satisfies the protection requirements of :
Electromagnetic compatibility

Electromagnetic compatibility
directives followed for EU
countries

Directive 89/336/EEC in conjunction with EN 61326-1(A1&A2)
and EN 61000-6-2 standards. It also respects the NAMUR NE
21/98 standard. Protection against EMC emissions is only
guaranteed when the device is used in metal tanks (except when
the device is equipped with coaxial probes).
Low voltage electrical equipment

Other EU directives

Directive 73/23/EEC modified by Directive 93/68/EEC (art.13) in
conjunction with the EN 61010-1 standard.
ATEX*

Directive 94/9/EC in conjunction with EN 50014, EN 50020 and
EN 50284 standards.
Refer to the BM 102 MICROFLEX KEMA 00 ATEX 1101X
Supplementary Installation and Operating Instructions for further
information.

Approvals

ATEX*
KEMA 00 ATEX 1101 X

II 1 G or II 1/2 D T 100 °C

EEx ia IIC T6 … T3 or EEx ia IIB T6 … T3

Factory Mutual Research*

Project ID 3009543

FM Class I, Div. 1, Gr. A, B, C, D and Class II, III, Gr. E, F, G
FM Class I Zone 0 AEx ia IIC T4 resp. AEx ia IIC T6

CSA*
Project 1183965 (Edition 1)
(KEMA: 2007223.00)

Class I, Div. A, B, C and D: Class II, Div. E, F and G; Class III;
Ambient temperature -30°C … +60°C or -20°F … +140°F; max.
product pressure 4000 kPa (580 psi).






* only approved if requested in customer order.