beautypg.com

KROHNE BM 102 EN User Manual

Page 21

background image

BM

102

21


3.3.2 HART

®

Communicator


Display and configuration can also be carried out via a HART

®

communicator. Operator control via

this unit is described in detail in the operating instructions supplied with the HHC.

Basic operating instructions for taking measurements

Communicator layout





1





Two-pin jack for loop connectors

2 LCD
3

Function keys (F1 … F4)

4 Action

keys

On/off UP

Arrow

n/a

LEFT

Arrow

DOWN

Arrow

RIGHT

Arrow


Other functions:-
LEFT Arrow: Previous menu key
RIGHT Arrow: Select key



Displaying readings
Use the UP and DOWN arrows to move to the correct line and then select with the RIGHT Arrow.

1

HART Communicator
1

Offline

2 →

Online

3

Frequency Device

4

Utility


2 BM102:00000 01

Online

1 →

2

3

4

5

SAVE

F1 F2 F3 F4

F1 F2 F3 F4

Main menu Online menu

3

BM102:00000 01

1 →
2




4 BM102:00000 01 ♥

1 →

878.00 mm

2

121.00 mm

SAVE

HOME

HELP

SAVE

HOME

F1 F2 F3 F4

F1 F2 F3 F4

Measurement & input and output functions menu Measurement display function