SWITCH A
FOR EACH "SWITCH A" TRUNKING OPTION (LISTED BELOW) — REFER TO THE
CORRESPONDING RECOMMENDED "SWITCH B" TRUNK OPTIONS (RIGHT FACING PAGE).
_
______________________________________________________________________________________
GROUP/CALL TYPE DIREC-
SUPERVISION
SIGNALING
_ ____________________
TION
_ ________________________________________________________
GENERIC 2,
GS LS RB E&M ISDN
INCOMING
OUTGOING
TIMEOUT
SYSTEM 85, OR
DIMENSION PBX
"ALERTING" "ADDRESSING"
(NOTE
3)
_
______________________________________________________________________________________
_
______________________________________________________________________________________
35/TIE IN
28 IMMED-START
(AUTOMATIC)
_
________________________________________________________
1
_
______________________________________________________________________________________
_
______________________________________________________________________________________
36/TIE 2W
D-4 IMMED-START
IMMED-START
(DIAL-REPEATING) (DIAL-REPEATING)
_
______________________________________________________________________________________
_
______________________________________________________________________________________
37/TIE 2W
31 IMMED-START
IMMED-START
(DIAL-REPEATING) (AUTOMATIC)
_
________________________________________________________
27
ANALOG LINE
ANALOG LINE
_
______________________________________________________________________________________
_
______________________________________________________________________________________
38/TIE 2W
28 IMMED-START
IMMED-START
(AUTOMATIC) (DIAL-REPEATING)
_
________________________________________________________
1
_
______________________________________________________________________________________
_
______________________________________________________________________________________
39/TIE 2W
32 IMMED-START
IMMED-START
(AUTOMATIC) (AUTOMATIC)
_
________________________________________________________
1
_
______________________________________________________________________________________
_
______________________________________________________________________________________
40/TIE IN
8 DELAY-DIAL
(Note
13)
(DIAL-REPEATING)
_
______________________________________________________________________________________
_
______________________________________________________________________________________
41/TIE 2W
D-26 WINK-START
WINK-START
OR
4-6
Sec
(DIAL-REPEATING) DELAY-DIAL
_
________________________________________________________
22 DELAY-DIAL
DELAY-DIAL
_
________________________________________________________
21 WINK-START
WINK-START
_
________________________________________________________
11 WINK-START
WINK-START
OR
(Note
13)
DELAY-DIAL
_
________________________________________________________
20 DMI-MOS
DMI-MOS (Note
5)
_
______________________________________________________________________________________
_
______________________________________________________________________________________
42/TIE IN
D-26 WINK-START
4-6
Sec
(DIAL-REPEATING)
_
________________________________________________________
22 DELAY-DIAL
_
________________________________________________________
11 WINK-START
(Note
13)
_
________________________________________________________
21 WINK-START
_
________________________________________________________
20 DMI-MOS
(Note
5)
_
______________________________________________________________________________________
Note:
14.
This trunk type is used for AUTOVON applications.