SYNCHRONIZATION OF DIGITAL FACILITIES

B-7

_

______________________________________________________________________________________

_

______________________________________________________________________________________

_

______________________________________________________________________________________

NOTE: For System 85 and Generic 2, the SCS provides a stratum-4 clock.

However, a stratum-3 external clock may be used instead of the SCS.

LEGEND

NOTE

..

..

..

..

..

..

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. . .

. . .

. . .

. . .

. . .

. . .

. . .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. . . . . .

. . . . . .

AT&T STANDARD REFERENCE FREQUENCY

DSO DSO

DSO

DCO

DCO

DACS

D4

SYSTEM

85

CEM

SYSTEM

75

SYSTEM

85

DEFINITY

G1 OR G2

DEFINITY

G1 OR G2

SYSTEM

75 OR 85

SECONDARY FREQUENCY REFERENCE

PRIMARY FREQUENCY REFERENCE

DIGITAL TRANSMISSION FACILITY

. . . . . . . . . . . . .

STRATUM 4

STRATUM 3

STRATUM 2

STRATUM 1

Figure B-3. Stratum Levels for the Synchronization Hierarchy

System 85 and Generic 2 Synchronization Architecture

Both System 85 and Generic 2 can function as either a timing slave or timing master. As a slave, the
switch receives digital data from one or two DS1s. One interface supplies the primary synchronization
reference and the other interface supplies the secondary reference. The timing source selected is
determined by the system clock synchronizer (SCS) TN463 circuit pack and synchronization software. The
SCS synchronizes (phase locks) to either the primary reference, secondary reference, or the internal high-
accuracy clock. Figure B-4, SCS (Generic 2), shows the SCS circuit pack.