beautypg.com

Technical data – KROHNE TIDALFLUX 2300 F EN User Manual

Page 39

background image

TECHNICAL DATA

6

39

TIDALFLUX 2300 F

www.krohne.com

06/2013 - 4002490202 MA TIDALFLUX 2300 F R02 en

EXAMPLE:

Consider a maximum flow to be measured of 1200 m

3

/h. The material of the pipeline is steel and

the slope 1.0%.

From the table a maximum flow has to be selected that is bigger than the flow to be measured.
Selection: DN500, Q

max

= 1767 m

3

/h and v

max

= 2.5 m/s.

To determine the level in the pipe at 1200 m

3

/h, calculated the ratio Q / Q

max

= 1200 / 1767 = 0.68.

See above figure and read out the ratio's of H/DN and v/v

max

:

1 H/DN = 0.6 or 0.6 x 500 mm = 300 mm,
2 At H/DN = 0.6, find v/v

max

= 1.05, so v = 1.05 x 2.5 = 2.63 m/s.

Figure 6-2: Relative flow and velocity versus relative filling level

1 Flow Q
2 Velocity v

INFORMATION!
v

max

and Q

max

are the values of v and Q if the pipe is completely filled

INFORMATION!
A sizing tool for various slopes is available at the website of the manufacturer.