4

ELECTRICAL CONNECTIONS

30

TIDALFLUX 2300 F

www.krohne.com

06/2013 - 4002490202 MA TIDALFLUX 2300 F R02 en

4.10 Grounding

4.10.1 Mounting grounding rings

4.11 Before switching on the power

Before switching on the power, please check that the system has been correctly
installed. This includes:

• The device must be mechanically mounted safely in compliance with the regulations.
• The power connections must be in compliance with the regulations.
• Make sure that all electrical connections are made and that the covers of the terminal

compartments are closed.

• Check that the electrical operating data of the power supply are correct.

• Switch on the power.

DANGER!
The device must be grounded in accordance with regulations in order to protect personnel
against electric shocks.

CAUTION!
In order to get a reliable height measurement it is absolutely necessary

absolutely necessary

absolutely necessary

absolutely necessary that the inner side of the

connecting pipeline is electrically conductive and connected to ground. If not, tailor-made
grounding rings with a cylindrical part can be delivered. Please contact your local agency in case
of doubt.

Figure 4-19: Grounding with grounding rings

1 Existing pipeline
2 Grounding rings, custom made to inner diameter of pipeline
3 TIDALFLUX
4 Insert the cylindrical part of the grounding ring into the pipeline. Use an appropiate gasket between the grounding ring

and the flange.

INFORMATION!
Sizes of the grounding rings are diameter dependent and available on request.

INFORMATION!
The sensor can not be programmed or changed in any way. All settable functions are included in
the converter. Please see the relevant documentation of the converter for more information.