background image

4

ELECTRICAL CONNECTIONS

18

TIDALFLUX 2300 F

www.krohne.com

06/2013 - 4002490202 MA TIDALFLUX 2300 F R02 en

4.3.1 Cable lengths

Interface cable

Interface cable

Interface cable

Interface cable: maximum length is 600 m / 1968 ft.

Type B (BTS) signal cable

Type B (BTS) signal cable

Type B (BTS) signal cable

Type B (BTS) signal cable: maximum length is 600 m / 1968 ft.

Type A (DS) signal cable

Type A (DS) signal cable

Type A (DS) signal cable

Type A (DS) signal cable: maximum length depends on the conductivity of the fluid:

Field current cable

Field current cable

Field current cable

Field current cable: The cross section of the cable determines the maximum length:

CAUTION!
The maximum allowed distance between the flow sensor and the converter is determined by the
shortest cable length.

Electrical conductivity

Maximum length

[µS/cm]

[m]

[ft]

50

120

394

100

200

656

200

400

1312

≥400

600

1968

Cross section

Maximum length

[mm

2

]

[AWG]

[m]

[ft]

2 x 0.75

2 x 18

150

492

2 x 1.5

2 x 16

300

984

2 x 2.5

2 x 14

600

1968