Technical data – KROHNE TIDALFLUX 2300 F EN User Manual
Page 37
TECHNICAL DATA
6
37
TIDALFLUX 2300 F
www.krohne.com
06/2013 - 4002490202 MA TIDALFLUX 2300 F R02 en
Electrical connections
General
Electrical connection is carried out in conformity with the VDE 0100
directive "Regulations for electrical power installations with line
voltages up to 1000 V" or equivalent national specifications.
Power supply
Standard: 100...230 VAC (-15% / +10%), 50/60 Hz
Option 1: 24 VAC/DC (AC: -15% / +10%, 50/60 Hz; DC: -25% / +30%)
Power consumption
AC: 22 VA
Field current cable
Shielded cable must be used, no part of delivery.
Signal cable
DS 300 (type A)
DS 300 (type A)
DS 300 (type A)
DS 300 (type A)
Max. length: 600 m / 1950 ft (dependent on electrical conductivity).
BTS 300 (type B)
BTS 300 (type B)
BTS 300 (type B)
BTS 300 (type B)
Max. length: 600 m / 1950 ft
Data interface cable
For transmission of measured level to IFC 300 F.
Shielded Liycy cable, 3 x 0.75 mm
2
Cable entries
Standard: 2x M20 x 1.5 + 2x M16 x 1.5 EMC type
Option: ½" NPT
Approvals and certificates
CE
CE
CE
CE
This device fulfills the statutory requirements of the EC directives.
The manufacturer certifies successful testing of the product by
applying the CE mark.
Electromagnetic compatibility
Directive: 2004/108/EC, NAMUR NE21/04
Harmonized standard: EN 61326-1 : 2006
Low voltage directive
Directive: 2006/95/EC
Harmonized standard: EN 61010 : 2001
Pressure equipment directive
Directive: 97/23/EC
Category I, II or SEP
Fluid group 1
Production module H
Hazardous areas
Hazardous areas
Hazardous areas
Hazardous areas
ATEX
Option: Ex zone 1, IECex
Other approvals and standards
Other approvals and standards
Other approvals and standards
Other approvals and standards
Protection category acc. to
IEC 529 / EN 60529
Standard: IP 66/67 (NEMA 4/4X/6)
Option: IP 68 (NEMA 6P)
Vibration resistance
IEC 68-2-6
Random vibration test
IEC 68-2-34
Shock test
IEC 68-2-27