INSTALLATION

3

13

TIDALFLUX 2300 F

www.krohne.com

06/2013 - 4002490202 MA TIDALFLUX 2300 F R02 en

3.6.6 Cleaning of flow sensor

The flow sensor is highly resistant against dirt and the measurement will rarely be influenced by

anything. However, it is advisable to create a possiblity for cleaning just in front or behind the sensor.

3.6.7 Flange deviation

3.6.8 Mounting position

Figure 3-9: Option for cleaning of flow sensor

1 Opening for cleaning

CAUTION!
Max. permissible deviation of pipe flange faces: L

max

- L

min

≤ 0.5 mm / 0.02"

Figure 3-10: Flange deviation

1 L

max

2 L

min

CAUTION!
Only install the flow sensor in the shown position to keep the electrodes under water. Limit the
rotation to

±

2

°

to maintain the accuracy.

Figure 3-11: Mounting position