HT instruments SIRIUS87 User Manual
Page 44
![background image](/manuals/367533/44/background.png)
SIRIUS
87
EN - 42
If the instrument finds a network
frequency out of range it does not
permit to effect the tests and displays
the message alongside.
LOOP
c
THIS RESULT CANNOT BE SAVED.
If under P-PE mode the instrument
carries out the test and detects a
resistance to higher than 1999
, the
screen alongside is displayed.
LOOP
>
1999
218
V
1
A
Under mode P-P o P-N if the
instrument detects a
resistance
higher than 199.9
the instrument
displays the alongside screen.
LOOP
>
199.9
P-N
218
V
1
A
SAVING:
The tests can be stored pressing the
SAVE key twice
(according to § 5.1).
Message
">199.9":
the instrument
detects a line
loop resistance
higher than
199.9
.
Value of voltage existing between the instrument’s
terminals (phase to phase if the test is P-P, phase
to neutral if the test is P-N).
Value of voltage existing between the instrument’s
terminals phase to earth
P-N or P-P
Message
“>1999”: the
instrument
detects an earth
resistance higher
than 1999
.
SAVE
SAVE
Message
“Err SYn cro”:
frequency is out
of range.