20
Judge:
Shows the test result judgment.
Set Limits
Upper Limit:
Displays the upper test limit.
Lower Limit:
Displays the lower test limit
Wait
Time:
Displays the wait time before a test
commences.
Meas Time
Measurement time.
Toggle the Set Limit display from
graphical to text mode. Graphical
mode graphs the results in real-time.
Clears the Max/Min test results
from the screen.
Power State
Displays the current power state settings.
Status
Displays the status of the test. There are three status
types.
Wait for Setting
Occurs when the instrument is
powered up or when the
measurement network, class or
leakage current mode has changed.
Ready
Occurs when the Meas key is pressed
after Network, Class or Leakage is
chosen.
Testing
Press the START button whilst in
Ready mode to enter Testing mode.
The RESET option will be displayed
when in Testing mode.