beautypg.com

GW Instek SPS Series User Manual

Page 7

background image

3

2-2. Constant Voltage Operation

(1) Output Voltage ranges from 0 to rating voltage with continuous adjustment.
(2) Voltage regulation

line regulation≦5mV.
load regulation≦5mV.

(3) Recovery time≦500μs(50% Load change, minimum load 0.5A).
(4) Ripple & Noise≦5mVrms, 100mVp-p (tested by 20MHz oscilloscope.)
(5) Temperature coefficient≦100ppm/℃.

2-3. Constant Current Operation

(1) Output current ranges from 0 to rating current with continuous adjustment.
(2) Current regulation

line regulation≦3mA.
load regulation≦3mA.

SPS-606

SPS-3610

SPS-2415

SPS-1820

SPS-1230

(3) Ripple & Noise

≦3mArms

≦5mArms

≦10mArms

≦10mArms

≦30mArms

2-4. Indicator Meter

1)Voltage:
Display

: 3 1/2 Digits 0.39” Green LED display.

Accuracy

: ±(0.5% of rdg + 2 digits).

2)Current:
Display

: 3 1/2 Digits 0.39” Red LED display.

Accuracy

: ±(0.5% of rdg + 2 digits).

2-5. Over Voltage Protection

(1) Over Voltage Protection ranges from 5% rating to rating +5.5%.
(2) OVP Accuracy ±(Vset 1%+0.6V)

2-6. Insulation

Between Chassis and Output Terminal

: ≧

20MΩ (DC500V).

Between Chassis and AC Cord

: ≧

30MΩ (DC500V).