2. SPECIFICATION

2-1. General

Main supply

: 115V/230V±15% 50/60Hz (Switch selectable).

Rating, dimension and weight

: See Table 2-1.

Table 2-1

MAX. RATING

INPUT RATING

FUSE STYLE & RATING

WEIGHT

Model

Voltage

Current

Watts

VA

115V

230V

kg

SPS-1230

12V

30A

SPS-1820

18V

20A

SPS-2415

24V

15A

SPS-3610

36V

10A

SPS-606

60V

6A

500

900

T 10A 250V

T 6.3A 250V

3.3

Dimensions:128(W) × 145(H) × 285(D) mm.

WARNING: Voltage over 60V DC is a lethal shock hazard to the user. Be careful when
connecting power supplies in series to achieve voltage higher than 60V DC totally or 60V
DC between any connection and earth ground.

Operation Environment

: Indoor use,

Altitude up to 2000m,
Installation Category II,
Pollution degree 2.

Operation Temperature &Humidity : 0℃ to 40℃, <80%.
Storage Temperature & Humidity

: -10℃ to 70℃, <70%.

Accessories

: Test Lead (current < 4A)……………………………………………

× 1

Operation Manual..…………………………………………………………. Ч 1