beautypg.com

GW Instek SPS Series User Manual

Page 18

background image

14

(4) Output Test lead Selection:

The Selection of Output Test Lead and Feedback Test Lead:

For safety assurance, please select the adequate output test lead according to the following list:

Conductor

UL

(CSA)
Model

Wire No.

AWG

Component

pc/mm

Cross Section Area

(mm)

2

Outer

Diameter

mm

Maximum

Conductive

Resistor

Ω/km

Permissible

Current
A(amp)

24

11/0.16

0.22

0.64

88.6

7.64

22

17/0.16

0.34

0.78

62.5

10.0

20

21/0.18

0.53

0.95

39.5

13.1

18

34/0.18

0.87

1.21

24.4

17.2

16

26/0.254

1.32

1.53

15.6

22.6

14

41/0.254

2.08

2.03

9.90

30.4

12

65/0.254

3.29

2.35

6.24

40.6

1015

TEW

(Twisted Wire)

10

65/0.32

5.23

3.00

3.90

55.3

Remark:

1. The ambient temperature of “Permissible Current” is at 40℃, the withstanding temperature of conductor is at 105

℃ according to the condition of the distributed single wire.

2. The permissible current listed as above is suggested to be used under 70%.
3. If the feedback test leads are in need, the level above UL(CSA) AWG24, 22, 20… can be accepted. Besides,

when the load is a capacitive load, please use the twine wire by twisting (+)output test lead with (S+) feedback
test lead. Same way used on (-) output test lead and (S-) feedback test lead.

4. When the current value exceeds above suggestive list, can select more wires used in parallel according to above

list.