FireLite SLC Wiring Manual — P/N 51309:P1 10/12/2011
Surge Suppression
Installation
B.2.2 Wiring Diagram for MS-9600, MS-9600LS, MS-9600UDLS,
MS-9200UD, MS-9200UDLS, and MS-9050UD
DTK-2LVLP-F Connections
PLP-42N Connections
SLCP-30 Connections
–
+
SLC Loop
SLC Terminal Block
S
L
C
-lv
lp
4
.w
m
f
Optional 4-wire Return Loop
Style 6 (Class A)
2LVLP-F
2LVLP-F
IN OUT
IN OUT
B+
A+
B-
A-
A Shield
B Shield
–
+
IN
P
U
T
OUTP
UT
L
1
L2
L3
L4
L1
L2
L
3
L4
GRND
INP
U
T
OUTPUT
L1
L2
L
3
L4
L
1
L2
L3
L4
GR
N
D
S
L
C
-p
lp
n
4.
w
m
f
SLC Loop
SLC Terminal Block
Optional 4-wire Return Loop
Style 6 (Class A)
PLP-42N
PLP-42N
B+
A+
B-
A-
A Shield
B Shield
NOTE: Use 12AWG (3.25mm2) to 18AWG (0.75mm2) wire with crimp-on connectors to connect
the unit’s ground terminal to equipment ground. Wire length must be minimized to provide best
protection.
+
–
S
L
C
-s
lc
p
4.
w
m
f
SLC Terminal Block
SLC Loop
Optional 4-wire Return Loop
Style 6 (Class A)
2LCP-30
IN OUT
IN OUT
2LCP-30
B+
A+
B-
A-
A Shield
B Shield
- 2401B Circuit Board Standoff Placement (1 page)
- 411UDAC Fire Alarm Communicator (84 pages)
- 411UDAC Dig C Digital Communica unicatortor (1 page)
- 411UDAC Communicator Dress Panel (2 pages)
- 411UDAC Communicator Circuit Board & Transformer (2 pages)
- 411UDAC Fire Alarm Communicator Relay (1 page)
- ACC-25/50 Audio Command Center (1 page)
- ACC-25/50DA Distributed Audio Panel (84 pages)
- ACC-25/50ZS (1 page)
- ACM-16ATF Annunciator Modules (68 pages)
- ACM-8RF Control Relay Module (48 pages)
- APS-6RF Auxiliary Power Supply (28 pages)
- B524BI Plug-in Isolator (4 pages)
- B524RB(A) Plug-in Relay Detector Bases (4 pages)
- B310LP Plug-in Base for Addressable Detector (2 pages)
- B350LP Plug-In Base for Addressable Detector (4 pages)
- BB-55 Battery Box (1 page)
- BG-12 Series Manual Pull Stations (4 pages)
- BG-12LA Manual Pull Station (2 pages)
- BG-12LAO Manual Pull Station (2 pages)
- BG-12LO Manual Pull Station (2 pages)
- BG-12LPS Pre-Signal Manual Pull Station (2 pages)
- BG-12LR Agent Release Pull Station (2 pages)
- BG-12LX Addressable Pull Station (2 pages)
- BG-12SL Single Action Pull Station (2 pages)
- Central Station Receiver (1 page)
- CHG-120 Series Addendum - For Connection Of 100 Amp Hour Batteries (2 pages)
- CHG-120F Battery Charger (28 pages)
- CHG-75 Battery Charger (32 pages)
- CHS-6 Chassis (1 page)
- CHS-6 Chassis for BB-6 Cabinet (1 page)
- CMP-2401B Fire Alarm Control Panel (36 pages)
- CP355 Plug-in Addressable Ionization Sensor (2 pages)
- CRF-300 Relay Control Module (2 pages)
- DACT-UD2 Digital Alarm Communicator/Transmitter (52 pages)
- DP-4XF Dress Panel Kit PID (2 pages)
- ECC-50/100 Emergency Command Center (108 pages)
- ECC-50WBU Backup Amplifier (1 page)
- ECC-50DA/E Distributed Audio Amplifiers (26 pages)
- ECC-FFT (1 page)
- FCPS Series Field Charger/Power Supply (48 pages)
- FCPS Series Field Software Change Procedure (2 pages)
- FHSC-RF FIREFIGHTERS HANDSET STORAGE BOX (1 page)
- ECC-FFT Firefighters Telephone (32 pages)
- H350 Addressable Thermal Sensor (2 pages)