fault and alert MessaGes

Call the technical support phone number listed on the back cover for further technical assistance or to locate a qualified service agent in

your area.

possIble causes - checK/repaIr

dIsplaYed fault/alert MessaGe

• The water heater’s control system is polarity sensitive and will lock

out and disable heating operation if the polarity of the power supply

is reversed. The control system will display the “AC Reversed”

Fault message on the LCD in this condition.
note: Electronic flame sensing requires correct power supply

polarity AND a proper earth ground to the water heater and the

Main Burner. The control system does not verify earth ground

but this should be checked first if ignition failure occurs. See the

Ignition Failure Fault message information below.

CHANGE

BACK

ADVANCED

AC Reversed

Fault occurred 2 mins ago

Power supply to water heater

has reversed polarity.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

• The control system has failed to ignite the Main Burner.
• Water heater is not properly grounded, loose or open ground wire

to the Main Burner.

• Dirty/corroded flame sensor, clean flame sensor with fine steel

wool (replace if damaged).

• Loose or open wiring to the flame sensor.
• Loose or open wiring to the 24 V Gas Valve.
• Supply gas turned off, low gas volume.
• Intake air and/or vent piping is restricted or improperly installed.
• Low or no manifold gas pressure to the Main Burner.

CHANGE

BACK

ADVANCED

Ignition Failure

Fault occurred 2 mins ago

The water heater has failed to

ignite the burner.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

• The control system has detected low current (AC amps) from the

Hot Surface Igniter. The control system monitors igniter current

and will declare this Fault condition if the current is not at or above

the programmed minimum requirement.

• Loose or open wiring to the Hot Surface Igniter.
• Damaged, worn or open circuit Hot Surface Igniter.

note: Hot surface igniters are wearing parts. Wear is directly

related to heating cycle count. Heating cycle count can be viewed

in the Heater Information menu. Increasing the Differential setting

reduces heating cycle count.

CHANGE

BACK

ADVANCED

Low Igniter Current

Fault occurred 2 mins ago

Igniter current is low.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

• The control system has detected the Blocked Exhaust Switch

contacts are open.

• The condensate drain is blocked filling the exhaust elbow with

water - clear the condensate drain.

• Loose or open wiring to the Blocked Exhaust Switch.
• Restricted/blocked vent piping - condensate trapped in low point.
• Excessive equivalent pipe length, exceeded the maximum number

of 90° elbows or wrong pipe size used in the vent piping system.

• Excessive wind outdoors pressurizing the vent system piping.
• Excessive negative air pressure in the installed space.

CHANGE

BACK

ADVANCED

Blocked Exhaust

Fault occurred 2 mins ago

The exhaust is blocked or

restricted. Ensure

condensate hose is draining.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)