MIXInG valves

Water temperature over 125°F (52°C)

can cause severe burns instantly

resulting in severe injury or death.
Children, the elderly and the

physically or mentally disabled are at

highest risk for scald injury.
Feel water before bathing or

showering.
Temperature limiting devices such as

mixing valves must be installed

when required by codes and to

ensure safe temperatures at fixtures.

Water heated to a temperature which will satisfy clothes washing, dish

washing, and other sanitizing needs can scald and cause permanent

injury upon contact. Short repeated heating cycles caused by small

hot water uses can cause temperatures at the point of use to exceed

the water heater’s temperature setting by up to 20°F (11°C).

Some people are more likely to be permanently injured by hot water

than others. These include the elderly, children, the infirm and the

physically/mentally disabled. Table 4 shows the approximate time-

to-burn relationship for normal adult skin. If anyone using hot water

provided by the water heater being installed fits into one of these

groups or if there is a local code or state law requiring a certain

water temperature at the point of use, then special precautions must

be taken.

In addition to using the lowest possible temperature setting that

satisfies the demand of the application a Mixing Valve should be

installed at the water heater (see Figure 8) or at the hot water taps

to further reduce system water temperature.

Mixing valves are available at plumbing supply stores. Consult

a Qualified Installer or Service Agency. Follow mixing valve

manufacturer’s instructions for installation of the valves.

table 4

Water Temperature

Time to Produce 2nd & 3rd

Degree Burns on Adult Skin

160°F (71°C)

About 1/2 second

150°F (66°C)

About 1-1/2 seconds

140°F (60°C)

Less than 5 seconds

130°F (54°C)

About 30 seconds

120°F (49°C)

More than 5 minutes

dIshwashInG MachInes

All dishwashing machines meeting the National Sanitation

Foundation requirements are designed to operate with water flow

pressures between 15 and 25 pounds per square inch (103 kPa

and 173 kPa). Flow pressures above 25 pounds per square inch

(173 kPa), or below 15 pounds per square inch (103 kPa), will result

in improperly sanitized dishes. Where pressures are high, a water

pressure reducing or flow regulating control valve should be used in

the line to the dishwashing machine and should be adjusted to deliver

water pressure between these limits.

HOT WATER

OUTLET

TO TANK

INLET

CHECK

VALVE

MIXING

VALVE

COLD

WATER

INLET

TEMPERED WATER

OUTLET

12” TO 15”

(30-38 cm)

CHECK

VALVE

fIGure 8.

space heatInG and potable water sYsteM

Your water heater is equipped with inlet/outlet connections for use in

space heating applications (see Figure 9). If this water heater is to be

used to supply both space heating and potable (drinking) water, the

instructions listed below must be followed:

• Be sure to follow the manual(s) shipped with the air handler or other

type heating system.

• This water heater cannot be used in space heating applications only.

• This water heater is not to be used as a replacement for an existing

boiler installation.

• Do not use with piping that has been treated with chromates, boiler

seal or other chemicals and do not add any chemicals to the water

heater piping

• If the space heating system requires water temperatures in excess

of 120°F, a mixing valve must be installed per the manufacturer’s

instructions in the potable hot water supply to limit the risk of scald

injury.

• Pumps, valves, piping and fittings must be compatible with potable

water.

• A properly installed flow control valve is required to prevent

thermosiphoning. Thermosiphoning is the result of a continuous flow

of water through the air handler circuit during the off cycle. Weeping

(blow off) of the temperature and pressure relief valve (T & P) or higher

than normal water temperatures are the fi rst signs of thermosiphoning.

• The hot water line from the water heater should be vertical past any

mixing valve or supply line to the heating system to remove air bubbles
from the system.

• Do not connect the water heater to any system or components

previously used with non-potable water heating appliances when
used to supply potable water.