ventInG sYsteM InspectIon

At least once a year a visual inspection should be made of the venting

system. You should look for:
1. Obstructions which could cause improper venting. The

combustion and ventilation air flow must not be obstructed.

2. Damage or deterioration which could cause improper venting or

leakage of combustion products.

Be sure the vent piping is properly connected to prevent escape

of dangerous flue gasses which could cause deadly asphyxiation.
Obstructions and deteriorated vent systems may present serious

health risk or asphyxiation.
Chemical vapor corrosion of the flue and vent system may occur

if air for combustion contains certain chemical vapors. Spray can

propellants, cleaning solvents, refrigerator and air conditioner

refrigerants, swimming pool chemicals, calcium and sodium chloride,

waxes, bleach and process chemicals are typical compounds which

are potentially corrosive.
If after inspection of the vent system you found sooting or

deterioration, something is wrong. Call the local gas utility to correct

the problem and clean or replace the flue and venting before

resuming operation of the water heater.

anode rod InspectIon

Each water heater contains at least one anode rod, which will slowly

deplete (due to electrolysis) prolonging the life of the water heater

by protecting the glass-lined tank from corrosion. Adverse water

quality, hotter water temperatures, high hot water usage, hydronic

heating devices, and water softening methods can increase the

rate of anode rod depletion. Once the anode rod is depleted, the

tank will start to corrode, eventually developing a leak.
Certain water conditions will cause a reaction between the anode

rod and the water. The most common complaint associated with

the anode rod is a “rotten egg smell” produced from the presence of

hydrogen sulfide gas dissolved in the water. IMPORTANT: Do not

remove this rod permanently as it will void any warranties. A special

anode rod may be available if water odor or discoloration occurs.

NOTE: This rod may reduce but not eliminate water odor problems.

The water supply system may require special filtration equipment

from a water conditioning company to successfully eliminate all

water odor problems.
Artificially softened water is exceedingly corrosive because the

process substitutes sodium ions for magnesium and calcium ions.
The use of a water softener may decrease the life of the water

heater tank.
The anode rod should be inspected after a maximum of three years

and annually thereafter until the condition of the anode rod dictates

its replacement.
NOTE: Artificially softened water requires the anode rod to be

inspected annually.
The following are typical (but not all) signs of a depleted anode rod:

• The majority of the rods diameter is less than 3/8”.
• Significant sections of the support wire (approx. 1/3 or more of

the anode rod’s length) are visible.

If the anode rod show signs of either or both it should be replaced.

NOTE: Whether re-installing or replacing the anode rod, check for

any leaks and immediately correct if found.
In replacing the anode:
1. Turn off electric supply to the water heater.
2. Shut off the water supply and open a nearby hot water faucet to

depressurize the water tank.

3. Drain approximately 5 gallons of water from tank. (Refer to

“Draining and Flushing” for proper procedures). Close drain

valve.

4. Remove old anode rod.
5. Use Teflon® tape or approved pipe sealant on threads and

install new anode rod.

6. Turn on water supply and open a nearby hot water faucet

to purge air from water system. Check for any leaks and

immediately correct any if found.

7. Restart the water heater as directed in this manual. See the

Repair Parts Illustration for anode rod location.