beautypg.com

Detcon SmartWireless CX User Manual

Page 7

background image

Sentinel CX

Sentinel CX Sensor Station IM

Rev. 1.4

Page 3 of 26

when the unit is ordered. The ‘Wet output connector provides 12V outputs for external alarms. The ‘Dry’
output connector provides dry contacts for external power to control external alarms.

All alarms can be configured as Energized/De-Energized, Latching/Non-Latching and Silenceable/Non-
Silenceable for the relays. This setup must be performed at the controller, refer to the controller manual for
more information.

1.4 Power Supply-Internal Rechargeable Battery and Charging

Accessory

SmartWireless® CX is powered by an internal rechargeable Smart Battery capable of delivering continuous
operation in a no alarm condition for two to eight weeks depending on the quantity and type of sensors tied
to the control panel. The internal re-chargeable battery pack shall only be charged in a non-hazardous area
where the required operating temperature limits are 0C to +45C. It may be used in the field and be
discharged in the temperature range of -20C to +60C.

CAUTION

The internal re-chargeable battery pack shall only be charged in a non-hazardous
area where the required operating temperature limits are 0C to +40C. Charging
outside this temperature range may degrade the life of the battery pack.

CAUTION

The Battery Pack Detcon PN

360-3S6PFP-290 contains an internal protection

circuit which maintains its safe operation against all potential hazard conditions.

CAUTION

No other Battery Pack except Detcon PN

360-3S6PFP-290 may be used in the

operation of this device.

The internal battery can only be recharged in a non-hazardous area and only using the Detcon supplied
Battery Charger Accessory that runs on AC power.

Detcon Approved Battery Charger Accessory Ratings:

AC Input Power

Voltage: 100-240 VAC, 50-60 Hz (requires correct PN version for optional 110 or 220 VAC use)
Current: 2.0 Amps maximum

DC Output Power

Voltage: 24+/- 1 VDC
Current: 3.1 Amps maximum

NOTE 1

No other Battery Charger or VDC input power source may be used with this CX Controller
product.