beautypg.com

Detcon 880S-N4X User Manual

Page 28

background image

880-N4X

880-N4X Instruction Manual

Rev. 1.0

Page 24 of 40

b) Select “Gas Type”, and input the gas type of the sensor. (i.e., H2S, LEL, CO2, etc.) Up to 10

characters maximum. The “Gas Type” entered here must match the “Gas Type” entered at the Main
880.


c) The Range of the sensor is transferred by the Main 880 and should not be changed in the Remote

Display. However, the decimal point must be set for the range to be displayed correctly. Therefore
ranges of 10 for a unit of 10ppm or 10% will be displayed as 100, likewise entries of 5 for 5ppm or
5% will be displayed as 500. To correctly place the decimal point in the entry, select the “Decimal
Place” box and enter the decimal point placement. (i.e., a “Range” entry of 100 with a “Decimal
Place” of 1 provides a range of 10.0, 10ppm or 10%. Likewise, a “Range” entry of 500 with a
“Decimal Place” of 2 provides a range of 5.00, 5ppm or 5%.)


7) Proceed through all channels, setting each channel’s “Channel Description” and “Gas Type” to that setup

in the Main 880. When all channels have been correctly set-up the unit should be ready for normal
operation.


This manual is related to the following products: