beautypg.com

Appendix, Specifications, 1 specifications – Detcon FP-700 User Manual

Page 40

background image

Model FP-700

FP-700 Instruction Manual

Rev. 3.0

Page 36 of 40

9. Appendix

9.1 Specifications

Sensor Type:

Continuous diffusion/adsorption type
Matched-Pair Catalytic Bead type
True plug-in replaceable type

Sensor Life:

3-5 years typical

Measuring Ranges:

0-100% LEL (Lower Explosion Limit)

Accuracy/ Repeatability:

±3% 0-50% LEL; ±5% 50-100% LEL

Response/Clearing Time:

T50 < 10 seconds, T90 < 30 seconds

Zero Drift:

<5% per year

Outputs:

Linear 4-20mA DC
RS-485 Modbus™ RTU

Electrical Classification:

Explosion proof

CSA and US (NRTL)

Class I, Division 1, Groups B, C, D (Tamb = -40°Cto +75°C)
Class I, Zone 1, Group IIB+H2

ATEX

EEx d IIB+H2 T4 (Tamb = -40°Cto +75°C)

Ingress Protection:

NEMA 4X, IP66

Safety Approvals:

C

CSA

US

Performance to ISA12.13.01-2000 and CSA22.2 #152

ATEX
CE Marking
SIL2 Certi

fi

ed to IEC 61508

Warranty:

Plug-in detector – 2 years
Transmitter – 2 years

Environmental Specifications

Operating Temperature:

-40°F to +167F°; -40°C to +75°C

Storage Temperature:

-40°F to +167F°; -40°C to +75°C

Operating Humidity:

0-99% RH (Non-condensing)

Mechanical Specifications

Dimensions:

7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)