beautypg.com

Modular mechanical design, 3 modular mechanical design, Figure 5 sensor assembly front view – Detcon FP-700 User Manual

Page 7: Figure 6 sensor assembly breakaway

background image

Model FP-700

FP-700 Instruction Manual

Rev. 3.0

Page 3 of 40

Program Switch #1

LED Display

Program Switch #2

MODEL

FP-700

detcon inc.

LEL Sensor

Splashguard Adapter

Lockdown Set-Screw

Figure 5 Sensor Assembly Front View

1.3 Modular Mechanical Design

The Model FP-700 Sensor Assembly is completely modular and made up of four parts (See Figure 6 for
Assembly Break-away):

1) FP-700 Intelligent Transmitter Module (ITM)
2) Field Replaceable Plug-in Combustible Gas Sensor
3) Model 700 Housing Bottom Assembly (contains the Housing Bottom, Flame Arrestor, Retaining Ring,

and rubber O-Rings)

4) Splash Guard.

NOTE: All metal components are constructed from electro-polished 316 Stainless Steel in order to maximize
corrosion resistance in harsh environments.

Housing Bottom
Locking Set-Screw

M

O

D

E

L

F

P

-7

0

0

d

e

tc

o

n

in

c

.

L

E

L

S

e

n

s

o

r

Splash Guard

O-Rings

Intelligent Transmitter Module

(ITM) Microprocessor controlled
circuit encapsulated in an
explosion proof housing

d

e

tc

o

n

in

c

.

Splashguard

Adapter

Plug-In replaceable
H2S Sensor

Magnetic
Programming
Switches

Lens and LCD
Display

Interconnect

Wiring

Figure 6 Sensor Assembly Breakaway