 Check Bridge Voltage (should be 2.7 +/- 0.2VDC).

 Check validity of span gas and flow rate (check MFG date on cal cylinder).

 If using Splashguard with Integral Cal Port, must use Calibration Wind Guard or air movement can

compromise span gas delivery.

 Make sure correct Cal Factor is set

 Check for obstructions through stainless steel sinter element (including being wet).

 Replace the plug-in sensor.

Clearing Fault

Probable Causes: Failed Sensor, Cal Gas not removed at appropriate time, problems w/ cal gas and delivery,
or Background combustible gases preventing clearing.

 Confirm that no combustible gasses are present in background.

 Check Bridge Voltage (should be 2.7 +/- 0.2VDC).

 Check validity of span gas and flow rate (check MFG date on cal cylinder).

 Make sure correct Cal Factor and Gas Factor is set

 Check for obstructions through stainless steel sinter element (including being wet).

 Replace the plug-in sensor.

Poor Calibration Repeatability

Probable Causes: Failed Sensor, use of wrong Cal Gas, problems w/ cal gas and delivery, or Poison or
Inhibitor Gases.

 Check for adequate Sensor Life.

 Check Bridge Voltage (should be 2.7 +/- 0.2VDC).

 Check validity of span gas and flow rate (check MFG date on cal cylinder).

 Check for obstructions through stainless steel sinter element (including being wet).

 Evaluate area for presence of poisoning or inhibiting gases as listed in Section 2.3.

 Increase calibration frequency.

 Note the sensor’s serial # and report repetitive problems to Detcon’s Repair Department.

 Replace plug-in sensor.

Unstable Output/ Sudden spiking

Possible Causes: Unstable power supply, inadequate grounding, or inadequate RFI protection.

 Verify Power source is stable.

 Verify field wiring is properly shielded and grounded.

 Contact Detcon to optimize shielding and grounding.

Nuisance Alarms

 Check condulet for accumulated water and abnormal corrosion on terminal blocks.

 If nuisance alarms are happening at night, suspect condensation in condulet.

 Add or replace Detcon’s Condensation Prevention Packet P/N 960-202200-000.

 Investigate the presence of any other combustible gases that may be causing sensor response.

Processor and/or Memory Faults

 Recycle power in attempt to clear problem