9.4 Configuration of measurement program

(Flue gas measurements) Select one of the 4 configurable measurement programs.

For each of the programs the following parameters can be configured:

CO ppm limit: adjustable value for the CO sensor protection. If the CO value in the flue gas
is higher than the adjusted value in the analyzer, the purge pump will be activated and the
sensor will be protected against high CO concentrations. (Optionalalal)

Selectable fuel types: choose and select from the available fuel type list

Measurement windows: configuration of what and where will be displayed in the 3 meas-
urement value windows.

Zoom – window: select what will be displayed in the zoom - window

Program name

The following programs have a pre configured:

“Test Program” indented for use at instrument maintenance and calibration

9.4.1 Setting the CO ppm limit values

The CO ppm limit can be adjusted in the window „Measuring program selection“.

Select one of the available programs (arrow up/down) then press the F1 key.

F1

,

,

Select one available program

F1

Open the CO ppm limit window

The CO-ppm limit value can be adjusted in 100 ppm
steps between 300 ppm and 4.000 ppm / 10.000
ppm

)

OK oder ESC

Return to the measurement window